AC Performance Power inc

Call Directions Website Contact the business

AC Performance Power inc Marine & Commercial Generator Specialists
Generator & Marine Diesel Propulsion Experts
Service • Diagnostics • Repairs • Maintenance

Boating season is almost here — now’s the time to get ahead of it ⚓️If your generator or engines have been sitting all w...
05/15/2026

Boating season is almost here — now’s the time to get ahead of it ⚓️
If your generator or engines have been sitting all winter, don’t wait until your first trip out to find a problem. A little prep now can save a lot of headaches later.
Spring service is in full swing and our schedule is filling up quickly.
At AC Performance Power, we handle everything you need to get back on the water with confidence:
✔ Preventative maintenance & full spring service
✔ Oil & filter changes, cooling system & electrical checks
✔ Fuel system inspection & polishing
✔ Diagnostics & repairs on all major diesel engines & generators
✔ Troubleshooting no-start issues & performance concerns
Experienced with all major brands including MTU, CAT, Detroit, Cummins & Yanmar.
Authorized dealer for Kohler, Westerbeke & Fischer Panda.
📍 Serving NY (Montauk to Manhattan), NJ & CT
Send us a message or call/text to get on the schedule — before the season kicks off.

04/29/2026

Part 2. From failure to full power in under 24 hours ⚡️

Here’s a look at the retrofit, rewire, and test that got this Cummins unit back online.

When a brand-new Cummins generator goes down, time matters. ⚡️AC Performance Power was brought in after the owner experi...
04/29/2026

When a brand-new Cummins generator goes down, time matters. ⚡️

AC Performance Power was brought in after the owner experienced ongoing issues with local OEM support. Our team quickly diagnosed a failure within the proprietary PCC network communication system originating from the base board.

While a genuine parts replacement was an option, we recommended a smarter long-term solution — retrofitting to an open-source controller to eliminate reliance on proprietary software.

From verification of CAN communication to a full system overhaul, our team removed the OEM electronics, installed, wired, programmed, and tested the new controller — restoring full operation in under 24 hours.

Reliable solutions. Faster results. Back to power.

Big job, done right. Installed 2 cylinder heads, replaced the full oil cooler assembly, fresh fluids & filters, primed t...
04/26/2026

Big job, done right. Installed 2 cylinder heads, replaced the full oil cooler assembly, fresh fluids & filters, primed the system, and put it through a full load bank test 💪

Unit is back online and ready when it matters most.

Out in Montauk performing a full generator load bank test.Accessed the vessel, set up in the engine room, and brought th...
04/09/2026

Out in Montauk performing a full generator load bank test.

Accessed the vessel, set up in the engine room, and brought the unit up to approximately 41 kW while monitoring voltage and frequency. The generator handled full load without issue and maintained stable output throughout testing.

We then transferred the vessel’s electrical load onto the generator and ran it under real operating conditions. The system ran smoothly with no faults or abnormalities.

Load testing is one of the most important ways to verify your generator will perform when you actually need it—under real demand, not just idle conditions.

We provide full load testing for both stationary and marine generators—for peace of mind on land or at sea.
📞 833-717-6937

Tracked down an undervoltage shutdown on a generator out in Hampton Bays and worked through full diagnostics—from pullin...
03/25/2026

Tracked down an undervoltage shutdown on a generator out in Hampton Bays and worked through full diagnostics—from pulling fault codes and reprogramming the controller to load bank testing and internal alternator inspection. Found a loose/split PCB causing instability, secured and reassembled, then verified repairs under 100% load. Final adjustments to governor and protection settings brought the unit back to reliable operation. Another one back in service.

Back in Setauket for a follow-up on this Hatteras project. This visit included machining the flywheel for proper starter...
03/18/2026

Back in Setauket for a follow-up on this Hatteras project. This visit included machining the flywheel for proper starter engagement, running multiple crank tests, and completing final assembly with a new starter and overspeed switch. Everything tested out smoothly—another step toward getting this system back to reliable operation.

For all your service needs, call 833-717-6937 or email [email protected].

🚢 Staten Island service callVessel reported coolant coming from the port exhaust.Diagnosis found a cracked turbo housing...
03/08/2026

🚢 Staten Island service call
Vessel reported coolant coming from the port exhaust.
Diagnosis found a cracked turbo housing allowing coolant into the exhaust system. Drained water from the exhaust, inspected the engine for hydro-lock, and confirmed the engine was in good shape.
Installed a new turbo, fabricated new cooling lines, and ran the engine to clear the system.
Engine is running clean and ready for service once the exhaust section is repaired.

Investigated a no-crank complaint and identified a worn ring gear. The unit was properly supported and disassembled, inc...
02/23/2026

Investigated a no-crank complaint and identified a worn ring gear. The unit was properly supported and disassembled, including removal of the stator, armature, and flywheel assembly. Ring gear service is in progress.

Repair Update:Here’s a look at the progress on our diesel generator rebuild. After completing detailed crankshaft measur...
02/20/2026

Repair Update:
Here’s a look at the progress on our diesel generator rebuild. After completing detailed crankshaft measurements and inspections, our team confirmed thrust and bearing conditions, corrected minor wear, and brought the rotating assembly back into specification. Main bearings were inspected, select lower shells replaced, and all components cleaned, torqued, and reinstalled to spec.
This step is critical to ensuring long-term reliability before reassembly continues. More updates coming as we move into the next phase of the rebuild.